A5984GLPTR-T Screening Overview
The A5984GLPTR-T is a part number with a defined set of screening parameters. For a purchasing or engineering shortlist, the useful first step is to separate the headline values that define fit from the figures that need a second look in the datasheet. The table below records the verified values available for this part.
| Screening parameter | Verified value |
|---|---|
| Operating voltage | 8 – 40 V |
| Output current | ±2 A |
| Package | 24-pin TSSOP with exposed thermal pad |
| Pin count | 24 |
| Operating temperature | –40 to 105 °C |
| Quiescent current | 10 μA |
| Supply current | 10 mA |
A buyer can use the table as a checklist rather than a summary. The operating voltage sets the rail window; the output current states the drive rating; the package and pin count determine the board footprint; the operating temperature sets the environmental band; and the two current-consumption figures describe different operating conditions. None of these values should be read as a performance claim beyond the stated parameter. Where a design has a condition that the fact sheet does not describe, the next step is to check the datasheet, not to infer a value from the headline.
The chart below places the two range parameters side by side for a quick screening view.

Operating Voltage Range: 8 V to 40 V
The operating voltage is stated as 8 – 40 V. That is the supply-voltage window a buyer should compare with the system’s available rail. The comparison is simple at screening level: the system’s minimum rail must not fall below the 8 V lower endpoint, and its maximum must not rise above the 40 V upper endpoint. If either condition fails, the part is outside the stated range and the design should not be shortlisted on this parameter alone.
Do not treat the range as a recommendation for a nominal rail; it is the stated operating window. A rail that sits inside both endpoints passes this check at screening level. A rail that crosses an endpoint does not.
The fact sheet does not give tolerance, transient or derating data for this parameter, so those points belong in the datasheet review. The single range value is enough to eliminate a mismatch, but it is not enough to confirm performance under every supply condition.
Output Current Rating: ±2 A
The output current is stated as ±2 A. The plus/minus notation describes a rating in both directions; it is not a statement that the part delivers 2 A in one direction only. Buyers should compare the load current in each direction with the 2 A magnitude. Any margin policy is a design decision, not a value from the fact sheet.
The single figure does not define continuous versus peak operation, per-channel allocation, or test conditions. Those details are not in the fact sheet, so they should not be assumed from the headline rating. A design that needs a different current interpretation should verify it in the datasheet before shortlisting.
For screening records, keep the ± sign with the value. Dropping it changes the meaning of the parameter. If a load is unidirectional, the rating still needs to be read against the stated ±2 A figure rather than converted into a different number.

Package, Pin Count, and Operating Temperature
The package is stated as a 24-pin TSSOP with an exposed thermal pad, and the pin count is 24. The package description and the pin count are consistent, so the mechanical check has two parts: the body style and the lead count. The exposed thermal pad is part of the package outline and should be matched to the board land pattern.

The operating temperature range is –40 to 105 °C. Compare the system’s stated operating limits with both endpoints. A system that operates outside either endpoint is outside the stated range; a system inside both endpoints passes this screening check.
The fact sheet does not provide thermal resistance, moisture sensitivity or package dimension data, so those items remain datasheet checks. The exposed thermal pad is a package feature to accommodate in the layout, not a performance figure in this data set.
Current Consumption Figures
The fact sheet lists two current figures: quiescent current at 10 μA and supply current at 10 mA. They are separate fields and should be recorded separately. The quiescent figure is the smaller unit value; the supply figure is the larger unit value. That difference in units is not a conversion instruction and does not make the two figures interchangeable.
A buyer preparing a screening record should keep the condition attached to each field. The fact sheet gives the values but does not give the test conditions, load, or state for either figure. Those conditions belong in the datasheet review.
Do not use the quiescent current as a substitute for the supply current, or the reverse, when comparing against a system budget. One figure does not replace the other, and neither should be carried into a design calculation without the corresponding datasheet condition.
How to Request a Quote
To request a quotation from NexCir for the A5984GLPTR-T, send the part number and the requirements that matter to your screening process: the available operating voltage, the load current in both directions, the package and pin-count check, the operating temperature range, and any documentation you need. NexCir can then review the request against the parameters in this guide.